Solution With these results from the lab unit it is assumed that one can give the evidence, that the B 300 units are (were) capable to get connected to another Fabric even no Full Fabric license key is installed if the user run a FOS version of 6.1.0a (the initial firmware these units got shipped with). After performing that downgrade and the hareboot from the switch, the ISLs went online and establish a valid connection to the SW 200E. The final downgrade from 6.2.2e was only possible by using the firmwaredownload -s command via CLI. ![]() ![]() At that point of time, the ISLs were still broken (segmented). ![]() Now the user had downgraded the B 300 from 7.0.0a via all interim versions to 6.2.2e.